1) Unit displays ".888".
   Replace battery with new 9 volt alkaline battery.
ASIII

2) Response is very slow.
   "If the fuel cell sensor is several years old, the slowness is likely due to the age of the cell. If the fuel cell still consistently produces accurate results on accuracy checks, it is not necessary to replace the fuel cell, but if speed in performance is critical, replacing the fuel cell will make the instrument perform as new."
ASIII

3) Display does not come on.
   "Try a new battery, but if the battery is not dead or disconnected, it is likely that a Reed Switch has been broken and needs to be replaced. "
ASIII

4) Takes forever to clean up.
   Reed Switch is not functioning and needs to be replaced or the fuel cell is old and can be replaced .
ASIII

5) How do I calibrate my ASIII?
   Use the More Information link to get to the calibration section.
ASIII More Information

6) What does it mean when ".999" appears on the display.
   If your Alco Sensor III has a serial number less than 1200000, this display message indicates that the A/D convertor has likely gone bad and needs to be replaced by a factory technician